RNC – IR

Based on the configured number of microphones and speakers, the panel will display two charts (for Amplitude and Phase) for each combination.

IR measurement can be started only when the object is in Farina mode. More about IR measurement in IR Measurement

It is possible to compare the current measurement with a previously saved one.

On the top of the IR view there are buttons which allow the user to perform the following actions:

  • Export – export data into a CSV file, the file contains real part and imaginary part, this can be performed also from PathP, PathV, PathPV tab
  • Import – Import data from CSV file and automatically sends it to the device, this can be performed also from PathP, PathV, PathPV tab
    • If the comparison is active it will be cleared
    • If import file contains data for PathPV and Virtual Microphones are disabled then data for them will be ignored
  • Compare – import second series from CSV file and display it on the chart for comparison purpose, this will not send any data to the device
  • Clear compare – remove the second series from the chart

If RNC has enabled Virtual Microphones then PathPV data will be exported. When Virtual Microphones are disbaled then all VM path data will be filled with zeros.