FIRA MIMO Panel

FIRA MIMO native panel allows you to configure the Mode of each enabled filter and to load coefficients as well. All the diagonal filters are active as this diagonal values are configured through additional parameters. In order to see the graphs, you need to import coefficients. Use ‘Import’ or ‘Import All’ option  to import coefficients.
To open the native panel, double-click on the FIRMIMO audio object in the signal flow designer.

A screenshot of a computer Description automatically generated

When the device is connected the filter states will not be in sync with the device until the states are received or the native panel is opened. Once the native panel is opened after a successful connection, the filter states will be transferred to the device.
Provide number of Taps to 384 and from additional parameters set all diagonal cell to 1 for Conf matrix high/ low as per below image.

A screenshot of a computer Description automatically generated

Amplitude/Phase: When the coefficients are given and “Amplitude/Phase” option is selected, the graph display the value as per below figure.

A screen shot of a graph Description automatically generated

Coefficients:  When the coefficients are given and the “Coefficients” option is selected, the graph displays the values as per below figure. You can change the graph style using the “Chart Style” option.

  • Line chart style: when “Chart Style” selected as Line, the Coefficients graph as per below image.
    A screen shot of a computer Description automatically generated
  • Dot chart style: when “Chart Style” selected as Dot, the Coefficients graph as per below image.
    A screenshot of a computer Description automatically generated

Group Delay: When the coefficients are given and “Group Delay” option is selected, the graph display the values as per below figure.

A screen shot of a computer Description automatically generated

Curves Legend: This option allows you to show the details of which graph tab (Amplitude/Phase, Coefficients, Group Delay) is selected.

  • On the selection of Amplitude/Phase graph tab Curves Legend will show below information.
    A screenshot of a computer Description automatically generated
  • On the selection of Coefficients graph tab and Chart Styles ‘Dots’, Curves Legend will show below information.
    A screenshot of a computer Description automatically generated
  • On the selection of Coefficients graph tab and Chart Styles ‘Line’, Curves Legend will show below information.
    A screenshot of a graph Description automatically generated
  • On the selection of Group Delay graph tab, Curves Legend will show the information below.
    A screenshot of a computer program Description automatically generated

Additional Functionalities

  • Flat : This is used to make the graph flat by making coefficients to 0.

Before you use “Flat” functionality.

A screen shot of a graph Description automatically generated

After you click on the “Flat” button, the graph will change as per below image.

A screenshot of a computer Description automatically generated

  • Import : This function is used to import the coefficients for a single active filter. Click on the “Import” button, enter the file path and then click Ok.
    All coefficients for the selected filter will be imported, as shown in the graph. If the number of coefficients does not match the number of taps as shown in the screenshot below, a warning pop up will appear. Click ‘Yes’ to import available coefficients or click ‘No’ to cancel the import.
    A screenshot of a computer Description automatically generated
  • Export : This option is used to export coefficients for selected active filter into csv file.
    A table with numbers and numbers Description automatically generated
  • Export All : This option is used to export all active filters in one go. Click on the “Export All” button, then enter the path and file name, then click Ok.
    A xml file will be created which have coefficients for each active filter. Below figure shows the example of the configuration of the active filters in the xml file. You can use Import All’ button to import back the exported file.A number lines on a white background Description automatically generated
  • Import All: This option is used to import all coefficients in one go. Click on the “Import All” button, enter the XML file path and then click Ok.
    All the given coefficients will be imported and can be seen in the graph. If there is a mismatch between xml file In and Out matrix with FIRMIMO panel In and Out matrix then error will be displayed, and import will fail. In below image filter (Out 1 In1) is not active and try to import this as well so error is prompted.
    A screenshot of a computer Description automatically generated
  • Read:  This is used to read from the target to display in the panel.
  • Send : This is used to send the values changed in panel to target.

Above mentioned functionality is similar to LowRate tab as well.